Overview
The MWS5 series of miniature microwave presence
detectors provide automatic control of lighting loads with
optional manual control. As a standalone product it is
designed to be fitted unobtrusively into ceiling tiles or solid
ceilings using the supplied clips.
Three models are available: premium, direct dim, and
analogue dim all of which will switch incandescent,
fluorescent and compact fluorescent lighting. The direct
dim variant controls DALI or DSI digital dimming ballasts
whilst the analogue dim variant controls 1-10V dimming
ballasts.
The unit detects movement using a microwave sensor and
turns the load on. When an area is no longer occupied the
load will switch off after an adjustable time out period.
All functionality is fully programmable using an IR handset.
Features
Miniature Microwave Presence Detector (standalone)
MWS5
Product Guide
Power supply
Microwave Sensor
Detects movement within the unit’s detection range,
allowing load control in response to changes in occupancy.
IR Receiver
Receives control and programming commands from an
IR (infrared) handset.
Light Level Sensor
Measures the overall light level in the detection area
Status LEDs
The LED flashes Red to indicate the following:
RJ11 connector
The sensor head has a flying lead with a RJ11 plug at the
end plugs into the RJ11 socket on the power supply.
Power supply
This power supply has a 6A relay. It also has connections
for an external switch that can be used to turn on the load
when absence detection mode has been set or raised /
lowered with dimming variants.
Walk Test LED active
when movement is detected
Valid setting received
Sensor head
Lens
which covers...
IR Receiver
Light Level Sensor
Status LED
Dimming version shown
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Product Guide

Overview The MWS5 series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual control. As a

Page 2 - Detection diagram

10 Dimensions Flush ring Flange mounting bracket Sensor head Power supply Brackets Base plate 25mm 19mm 43mm 1mm Ø50.5mm

Page 3 - Sensor functionality

11 This page intentionally left blank

Page 4

12 Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior not

Page 5 - Wiring diagrams

2 Detection diagram Please note that these approximate distances will apply with the sensitivity set to maximum.

Page 6 - Power-up test procedure

3 The detector should be sited so that the occupants of the room fall inside the detection pattern shown opposite). Please note that when ceiling mo

Page 7 - SHIFT 1 SHIFT 2

4 Ø19.5mØ3.5m19mm Panel mounting using lugs Flush mounting Flush fitting behind light fitting diffuser using the flange mount bracket Use the lugs o

Page 8

5 Wiring diagrams Wire the products as shown in the diagrams. All switches are optional, however the dimming variants can have two switch configurat

Page 9 - Advanced programming

6 The UNLCDHS has the ability to read back the settings stored in a device. To read back individual parameters  Navigate to the parameter and pres

Page 10 - Dimensions

7 Basic programming - PRM, DD and AD variants Parameter Name Default Value 0 1 2 3 UHS5 Handset Graphics Description Button Activation

Page 11

8 Advanced programming Parameter Name Default Value Range / Options Description UHS5 UNLCDHS Detector Parameters Walk Test LED Off On or O

Page 12 - Part numbers

9 Parameter Name Default Value Range / Options Description UHS5 UNLCDHS Channel 1 –Switching Channel Detection Mode Presence Presence or A

Comments to this Manuals

No comments