Overview
The MWS6-DD microwave presence detector provides
automatic control of lighting loads with optional manual
control. The MWS6-DD detects movement using a highly
sensitive microwave detector. This works by emitting low
power microwave signals and measuring the reflections as
the signals bounce off moving objects.
Output Channel 1 comprises a mains voltage relay capable
of simple on/off switching, while Output Channel 2 provides
dimmable control of either DALI or DSI type ballasts.
Functioning as a presence detector, the unit can turn lights
on when a room is occupied and off when the room is
empty. Optional settings allow lights to be turned off in
response to ambient daylight, or to implement a maintained
illuminance (daylight harvesting) system.
The flexibility of having two channels and two switch inputs
allows the following example scenarios:
Dim an outside row of luminaires whilst internal fittings
are switched
Provide absence detection for two separate channels
Maintained illuminance system with manual up/down
controls
All functionality is fully programmable using an IR handset.
Features
Back features
Ceiling microwave presence detector DALI / DSI
MWS6-DD
Product Guide
Retaining Spring
Retaining Spring
Power Input
& Switched
Output Connector
(Channel 1)
Dimmable
Control Output
Connector
(Channel 2)
Switch Input
Connector
Microwave Sensor
Detects movement within the unit’s detection range,
allowing load control in response to changes in occupancy.
IR Receiver
Receives control and programming commands from an
IR (infrared) handset.
Light Level Sensor
Measures the overall light level in the detection area
Status LEDs
The LED flashes Red to indicate the following:
Power Input & Switched Output Connector (Channel 1)
Used to connect mains power to the unit and to connect a
switched load.
Dimmable Control Output Connector (Channel 2)
Used to connect DSI/DALI controllable ballasts and
transformers for dimmable loads.
Switch Input Connector
Two input terminals can be used to manually override the
dimming levels and override the lights on or off.
Walk Test LED active
when movement is detected
Valid setting received
Front features
Sensor Lens
which covers...
Microwave Sensor
IR Receiver
Light Level Sensor
Status LEDs
Mounting Bezel
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - MWS6-DD

Overview The MWS6-DD microwave presence detector provides automatic control of lighting loads with optional manual control. The MWS6-DD detects mo

Page 2 - Detection diagram

10 Parameter Name Default Value Range / Options Description UHS5 UNLCDHS Channel 1 –Switching Channel Detection Mode Presence Presence or

Page 3 - Burn-in

11 This page intentionally left blank

Page 4

12 Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior not

Page 5 - Wiring diagrams

2 Detection diagram Area of lower sensitivity Area of high sensitivity Note. If the range is compromised by the ceiling construction / material. Add

Page 6 - Two channel, single switch

3 Choosing a Suitable Location The detector should be sited so that the occupants of the room fall inside the detection pattern shown opposite). 

Page 7 - Single channel switching

4 Installation The MWS6-DD is designed to be mounted using either:  Flush fixing, or  Surface fixing, using the optional Surface Mounting Box (p

Page 8 - SHIFT 1 SHIFT 2

5 Single channel dimming Channel 1 (switched output) of the MWS6-DD can either be used to switch a separate channel of standard, non-dimming luminai

Page 9

6 L/OUTLNEBDSPIR-DD SENSORSW1/UPSW2DOWNPLEASE NOTE THAT THEDIMMING SIGNAL IS USED TOSWITCH THE DIMMINGLUMINAIRE ON/OFF ANDTHEREFORE THE 240V FEEDTO

Page 10 - Advanced programming

7 When power is applied to the unit, the load will turn on immediately. Set the timeout to 10 seconds, vacate the room or remain very still and wait

Page 11

8 Basic programming Parameter Name Default Value 0 1 2 3 UHS5 Handset Graphics Description Button Activation On / Raise On Raise

Page 12 - FM 45789 EMS 534520

9 Advanced programming Parameter Name Default Value Range / Options Description UHS5 UNLCDHS Detector Parameters Walk Test LED Off On or O

Related models: VITM6-EBDSPIR-DD | VITM6-EBDSPIR-AD |

Comments to this Manuals

No comments